Siemens LC 500 Benutzerhandbuch

Seite von 122
7ML19985GE01
SITRANS LC 500 – INSTRUCTION MANUAL
Page 1
m
mmmm
Intr
oduct
io
n
SITRANS LC 500 
SITRANS LC 500 is a high performance 2-wire capacitance instrument for continuous level 
and interface measurement in extreme or critical conditions. It uses a unique frequency-
based measurement system and patented Active-Shield technology to deliver highly 
accurate, repeatable results. The measurement is unaffected by moisture, vapors, foam, 
temperature and pressure variations, or material build-up around the mounting glands.
SITRANS LC 500 combines a sophisticated, easy-to-adjust transmitter (MSP-2002-2) with a 
measurement electrode and process seal selected from a range of options
1
, to suit a wide 
variety of applications. The advanced electronics and integrated local display provide for 
one-step calibration without interrupting the process, and the probe shield design eliminates 
the need for frequent recalibration. 
SITRANS LC 500 can be used as a level controller, by connecting the mA output and/or the 
solid-state switch to a relay, and activating a pump via an auxiliary power circuit.
The SITRANS LC 500 is equipped with: 
• Smart 2-wire transmitter
• Remote adjustable commissioning / control capabilities via HART
2
• Analog (2-wire) 4 to 20mA / 20 to 4 mA output
• Solid-state and Current detection (4 or 20 mA / 20 or 4 mA, two-state 
functionality)
• Adjustable hystereses on/off for solid-state output and for current signal
• Damping functionality
• Signal current (measurement/detection) according to NAMUR NE 43
• Integrated local display for commissioning and services activities
• Full range of local/remote diagnostic facilities
• Pre-detection of trip point for high safety requirements
• Polarity-insensitive current loop
• Integrated zener safety barrier for Intrinsically Safe applications
Applications
General Purpose, Dust Ignition Proof, Explosion Proof, and Intrinsically Safe
A wide range of applications in high pressure and temperature, chemically 
aggressive, and other extreme measurement/detection environments
Liquids, Solids, Quality, and Interface measurement
Viscous non-conducting and conducting liquids
1.
Customized probe configurations can also be provided.
2.
HART® is a registered trademark of the HART Communications Foundation, 
Austin, Texas, USA.