6.23.4 Operation example
(1) When other axes start is complete
The other axes start notice (OSOP) turns on between the axis start and the completion of the other axis
start. The other axes start complete (OSFIN) turns on when the other axes start notice (OSOP) is turned off
on completion of the other axes start.
start. The other axes start complete (OSFIN) turns on when the other axes start notice (OSOP) is turned off
on completion of the other axes start.
Other axes start condition satisfied
Other axes start notice
(OSOP )
(OSOP )
During operation (OP)
Start operation (ST)
Axis
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Other axis
During operation (OP)
ON
OFF
OFF
Other axes start
complete (OSFIN )
Other axes start
incomplete (OSERR )
complete (OSFIN )
Other axes start
incomplete (OSERR )
Digital output signal
(DO_000)
(DO_000)
ON
OFF
OFF
[Digital output signal setting example]
Address Abbreviation
Name
Setting value
Setting contents
E158 OSDOS
Digital
output
signal
specification 0001h
Digital output signal control: valid,
digital output signal number: 00h
digital output signal number: 00h
E15A
OSDOE
Digital output signal enable selection
0001h
bit0: valid, bit1 to bit15: invalid
E15C
OSDOP
Digital output signal command
0001h
bit0: ON