Mitsubishi Electronics MR-MC241 Benutzerhandbuch

Seite von 658
 
 
6 - 69 
6. APPLICATION FUNCTIONS 
 
6.23.4 Operation example 
(1) When other axes start is complete 
The other axes start notice (OSOP) turns on between the axis start and the completion of the other axis 
start. The other axes start complete (OSFIN) turns on when the other axes start notice (OSOP) is turned off 
on completion of the other axes start. 
Other axes start condition satisfied
Other axes start notice
(OSOP   )
During operation (OP)
Start operation (ST)
Axis
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Other axis
During operation (OP)
ON
OFF
Other axes start
complete (OSFIN   )
Other axes start
incomplete (OSERR   )
Digital output signal
(DO_000)
ON
OFF
 
 
[Digital output signal setting example] 
 
Address Abbreviation 
Name 
Setting value
Setting contents 
E158 OSDOS 
Digital 
output 
signal 
specification  0001h 
Digital output signal control: valid,  
digital output signal number: 00h 
E15A 
OSDOE 
Digital output signal enable selection
0001h 
bit0: valid, bit1 to bit15: invalid 
E15C 
OSDOP 
Digital output signal command 
0001h 
bit0: ON