Mitsubishi Electronics MR-MC241 Benutzerhandbuch

Seite von 658
 
 
7 - 26 
7. AUXILIARY FUNCTION 
 
7.8 Software reboot function 
Through using the software reboot function, the host controller can restart the position board using software. 
Perform the software reboot according to the following procedure. (Refer to the system data table for the 
command/status signal.) 
Turn on reboot 
preparation signal (RBR)
Turn on execution of 
reboot signal (RBS)
Start
Set reboot ID
No
Yes
Is the reboot
preparation OK?
(RBOK = ON?)
* Set reboot ID to 1EA5.
Finish
sscReboot function
 
 
 
POINT 
 
When reboot preparation is turned on, it becomes a forced stop status. 
If an erroneous reboot ID is set and reboot preparation turned on or execution 
of reboot turned on without performing reboot preparation, a reboot 
preparation error occurs. If a reboot preparation error occurs, turn off reboot 
preparation and execution of reboot and restart the process from the 
beginning. 
 
API LIBRARY  
Use the sscReboot function to perform software reboot.