7. AUXILIARY FUNCTION 
 
7.12.6 Number of sampled points 
By setting the number of sampled points (sampling setting No.0002), points to be sampled can be changed. 
Number of data which is sampled before the trigger conditions are met (set with pre-trigger) is specified by 
percentage to the number of sampled points. However, when the number of sampled points exceeds 8192, the 
percentage is to 8192. 
For when the number of sampled points is 8192 or less, and 8193 or more, the characteristics are shown 
below. 
 
(1) When the number of sampled points is 8192 or less 
When sampling of the points set in the sampling points (sampling setting No.0002) is completed, sampling 
itself is completed automatically. Since the host controller is required to read the sampling data buffer area 
after the sampling is completed, the load on the host controller is light, however, on the other hand, 
sampling for a long time cannot be executed. 
 
(2) When the number of sampled points is 8193 or more 
Points which are set to the sampling points (sampling setting No.0002) are sampled by the position board. 
However, the host controller is required to read sampled data during the sampling, the load on the host 
controller is high. 
The sampling data buffer area of the position board internal memory is regarded as the ring buffer of 256 
pages (8192 points), and the host controller and the position board read the sampling data read area with 
executing exclusive control based on the page number. 
 
 
POINT 
 
The larger the pre-trigger setting is, the higher the load on the host controller 
is since it is required to read the sampling data in a short time after the trigger 
conditions are met. As an example, when pre-trigger is set to 90%, after the 
trigger conditions are met, the host controller is required to complete reading 
the data sampled by pre-trigger (at least 1 page) before the position board 
completes the sampling of 10% left.