7. AUXILIARY FUNCTION 
 
7.14 Operation cycle monitor function 
7.14.1 Summary 
The operation cycle monitor function is a function that monitors the operation cycle current time, operation 
cycle maximum time, and operation cycle over time. The operation cycle monitor function becomes valid after 
the system starts. 
 
The operation cycle is the position board processing (SSCNET communication process   motion  operation 
process) time. 
SSCNET
communication
process
Motion
operation
process
ON
OFF
Control cycle
ON
OFF
Operation cycle
 
When the operation cycle exceeds the warning level (95% of the control cycle, 0.84ms when control cycle 
0.88ms is selected), the operation cycle warning signal (OCMW) turns on. Also, when the operation cycle 
exceeds the alarm level (100% or more of the control cycle, 0.88ms or more when control cycle 0.88ms is 
selected), the count of the operation cycle over time (address 0018h) increases and the operation cycle alarm 
signal (OCME) turns on. 
 
 
7.14.2 Interface 
Interfaces related to the operation cycle monitor function are shown below. 
 
(1) System command 
 
(2) System status 
Address Bit Abbreviation 
Signal 
name 
 
Address
Bit Abbreviation
Signal name 
03EA 0  LOGC Log command 
 
045A 
0
LOGO 
Log operation being performed 
 
LOGR 
Reading of log data command 
 
 
1
LOGRF 
Reading of log data complete 
 2    Reserved 
 
 
2
LOGRE 
Reading of log data error 
 
LOGI 
Log data initialization command
 
 
3
LOGIF 
Log data initialization is complete
 4    Reserved 
 
 
4
LOGIE 
Log data initialization error 
 
OCMC 
Operation cycle monitor clear 
 
 5
OCMCO 
During operation cycle monitor 
clear 
 6    Reserved 
 
 
6
OCME 
Operation cycle alarm 
 7   
 
 
7
OCMW 
Operation cycle warning 
 
(3) Operation cycle monitor data 
 
Address Size 
Name 
Unit 
Description 
0014h 
2 byte  Operation cycle current time 
 s 
Current processing time is stored 
0016h 
2 byte  Operation cycle maximum time 
 s 
Maximum processing time is stored 
0018h 
2 byte  Operation cycle over time 
Number of times The cumulative value of the number of times which 
exceeds the control cycle is stored