Mitsubishi Electronics MR-MC241 Benutzerhandbuch

Seite von 658
 
 
1 - 23 
1. SUMMARY 
 
1.7 Forced stop input terminal 
(1) Table of the forced stop input terminal specifications 
 
Item Specifications 
Number of input points 
Forced stop signal: 1 point 
Input method 
Positive common/Negative common shared type 
Rated input current 
2.4mA 
Isolation method 
Photocoupler 
Operating voltage range 
20.4 to 26.4VDC 
(+10/ -15%, ripple ratio 5% or less) 
ON voltage/current 
17.5VDC or more/2.0mA or more 
OFF voltage/current 
1.8VDC or less/0.18mA or less 
Input resistance 
Approx. 10k  
Response time 
OFF to ON 
1ms or less 
ON to OFF 
External connector type 
3 pin connector 
Recommended wire size 
0.08 to 0.32mm
(AWG22 to AWG28) 
 
(2) Forced stop circuit 
(a) Positive common 
+24V
24G
EMI.COM
EMI
Forced stop input connector
Forced stop
Control
circuit
Position board side
10k
Stabilizing power supply
 
 
(b) Negative common 
EMI.COM
EMI
Forced stop input connector
Forced stop
Control
circuit
Position board side
10k
+24V
24G