Mitsubishi Electronics MR-MC241 Benutzerhandbuch

Seite von 658
 
 
 
App. - 35 
APPENDIX 
 
App. 5.8 Control option 1 setting 
When controlling servo amplifier, set "1: control" for control axis of control option 1 (parameter No.0200). When 
the axis No. is set out of the controllable range, the corresponding axis will be system setting error (alarm No. 
38) and cannot be controlled. If the servo amplifier set is in a state where communication cannot be made, 
such as not connected or control circuit power is off, the "An axis that has not been mounted exists" (system 
error E400) will occur at the time of system startup (system command code: 000Ah). 
 
POINT 
 
If the "An axis that has not been mounted exists" (system error E400) 
occurred, the axis with wrong No. set can be confirmed with "information 
concerning axis that is not mounted" (monitor No.0402). 
 
 
Control axis settings are imported during system startup (system command code: 000Ah), and cannot be 
changed during system running (system status code: 000Ah). 
 
(a) Control parameter 
 
Parameter 
No. 
Abbreviation Name  Initial 
value Units
Setting 
range 
Function 
0200 *OPC1 
Control 
option 1 
0000h  
0000h 
to 
2111h 
Control axis
Set 1 when controlling servo
amplifier.
0: Do not control
1: Control
Servo amplifier disconnect
Set 1 when not communicating
with servo amplifier.
When setting 1 with control axis,
operation without servo amplifier
(simulation) is available.
0: Invalid
1: Valid
No home position
Set 1 when setting the position at
the time of power on as the home
position. After returning to home
position, the home position will be
the position where home position
return is complete.
0: Invalid
1: Valid
Speed unit
Set the speed command unit.
0: Position command unit / min
1: Position command unit / s
2: r/min
 
 
 
POINT 
 
When the servo amplifier disconnect is valid, the position board simulates the 
operations of servo amplifier and operates as if it is connected. Operation can 
be checked without connecting the servo amplifier. When the setting is valid, 
the position board do not communicate with the servo amplifier.