App. 5.13 Restrictions when using J3 compatibility mode 
The restrictions when connecting SSCNET  for position board and servo amplifier MR-J4(W )- B are shown 
in the following table. 
 
Position board 
SSCNET 
communication 
method 
MR-J4(W )- B 
mode 
Controller reset 
necessity (Note) 
Details 
SSCNET  
Factory default 
Necessary 
The servo amplifier LED displays "rST". 
The system status code is not system running (000Ah). 
After system start up, if the system status code is not system 
running (000Ah) after 10 seconds, or a system error occurs, perform 
system startup procedure again after controller reset. 
J3 compatibility 
mode 
Not necessary 
The system status code becomes system running (000Ah) when all 
axes are connected normally. 
J4 mode 
— (Cannot connect)
The system status code is not system running (000Ah). 
Review the settings of the servo amplifier or position board. 
SSCNET /H 
Factory default 
Not necessary 
The system status code becomes system running (000Ah) when all 
axes are connected normally. 
J3 compatibility 
mode 
— (Cannot connect)
The system status code is not system running (000Ah). 
Review the settings of the servo amplifier or position board. 
J4 mode 
Not necessary 
The system status code becomes system running (000Ah) when all 
axes are connected normally. 
Note. To perform a controller reset, execute a software reboot of the position board, or turn the power supply of the position board OFF 
and ON again. 
 
When position board SSCNET communication method is SSCNET  and a factory default MR-J4(W )- B 
servo amplifier is connected by SSCNET, the servo amplifier switches to J3 compatibility mode and the LED 
displays "rST". In this state, executing a controller reset (software reboot, or turning the power supply of 
position board OFF and ON again) and performing system startup procedure again enables all axes to be 
connected. 
When connecting by SSCNET  from the next time onwards, a controller reset is not necessary. When a 
controller reset cannot be executed, use the "MR-J4(W)-B mode selection" attached to MR Configurator2 to 
manually switch the servo amplifier to J3 compatibility mode in advance. 
For details on J3 compatibility mode, also refer to the MR-J4(W )- B Instruction Manual. 
 
 
POINT 
 
Do not connect a factory default MR-J4(W )- B servo amplifier by SSCNET 
reconnect afterwards. If SSCNET is disconnected once, system error E4
 
occurs and all axes go into a forced stop state.