Mitsubishi Electronics MR-MC241 Benutzerhandbuch

Seite von 658
 
 
4 - 4 
4. SYSTEM STARTUP 
 
4.4 Servo amplifier setting 
(1) MR-J4(W )- B  
Axis No. of MR-J4(W )- B is set by the axis selection rotary switch (SW1) and the axis No. auxiliary 
setting (SW2) on the servo amplifier. 
ON
3
2
1
4 5 6
Axis No. auxiliary setting switch
1 2 3 4
Note. For when set with the axis No.
 auxiliary setting
3-digit, 7-segment LED
Axis selection rotary switch
Axis 1 to 20
ON
Axis selection rotary switch
Axis 1 to 20
3-digit, 7-segment LED
Note. For when set with the axis No.
auxiliary setting
MR-J4W   -   B
MR-J4-   B
Axis No. auxiliary setting switch
 
Servo amplifier 
axis No. 
Axis selection 
rotary switch 
Axis No. auxiliary 
setting switch 
Servo amplifier display 
(3-digit, 7-segment LED) 
d1 0 
ON
OFF
 
01 
d2 1 
02 
d3 2 
03 
d4 3 
04 
d5 4 
05 
d6 5 
06 
d7 6 
07 
d8 7 
08 
d9 8 
09 
d10 9 
10 
d11 A 
11 
d12 B 
12 
d13 C 
13 
d14 D 
14 
d15 E 
15 
d16 F 
16 
d17 0 
ON
OFF
 
17 
d18 1 
18 
d19 2 
19 
d20 3 
20