5. OPERATIONAL FUNCTIONS 
 
5.3.4 Other axes start specification 
Set other axes start data number (1 to 32). When the other axes start data number is set, the position board 
starts the other axes according to other axes start conditions and operation details of their start data. Up to 2 
other axes start data number can be set. For details of other axes start function, refer to Section 6.23. 
 
POINT 
 
 If the setting of the other axes start specification is incorrect, it causes a point 
table setting error (operation alarm 25, detail 09) and operation is stopped. 
 
 
5.3.5 S-curve ratio 
Perform S-curve acceleration/deceleration for acceleration/deceleration selected in speed options (parameter 
No.0220). For automatic operation, this setting is valid regardless of the setting of S-curve ratio (parameter 
No.0221). 
0: S-curve acceleration/deceleration invalid 
1 to 100: S-curve acceleration/deceleration