− There are two options for measuring depth. 
Live depth is a continuous measurement. 
1-Shot Depth is an averaging of the depth 
reading over a short period of time. When in 
1-Shot mode, the unit will average the depth 
reading for three seconds, and then display 
the result on the display. Press Depth [SK] to 
alternate between the two modes.
 
− Five depth readings can be saved with the 
time, date and relative current measurements.
3.  Pressing Save [SK] will place each entry in sequential order in memory (M1 - M5) 
until five readings have been stored. The unit will overwrite saved entries in excess 
of five, beginning with M1.
4.  Press Clear All [SK] to delete all stored depth 
information.
 
− The operator may select the memory location 
to store the depth readings by pressing Mem 
Select [SK]. When the preferred location 
appears on the display, press Save [SK]. The 
display and memory location will populate 
with the current information.
 
− Each memory location can be reviewed by 
pressing Mem Select [SK].
5.  Press Locate/OK [5] to return to Locate Mode.
9. Locating Frequencies
A. Active Frequencies
Active frequencies are trace signals supplied by a 3M
 Dynatel
 Transmitter 2200 
Series (577 Hz, 8 kHz, 33 kHz, or 200 kHz).
1.  Select the same frequency that the transmitter is generating.
2.  Press Locate/OK [5]
3.  Press Cable/Pipe [SK]
4.  Press Freq [SK]
5.  Press Active [SK Toggle] until the desired frequency is displayed in the soft key 
command [9] (“Active” 577, 8K, 33K or 200K)
6.  Press Locate/OK [5] to return to Locate mode.