3M 530 Benutzerhandbuch

Seite von 6
78-8135-7466-8-B
1.0  Kit Contents
Note: Visually inspect all components. If any component is missing or appears damaged, do not install.  
Call 3M customer service at 1-800-426-8688 for a replacement product.
1.1 
Kit Contents SLiC 530/533/733-2 Port 0.61 Cable 
Entry Bracket 80-6113-2344-7
A.  Cable Addition Bracket Assembly (1) 
B.  Cap
C.  Multi-port Grommet (1) 
D.  Hose Clamp (1) 
E.  Pair Saver
F.  3M
 Scotchlok
 Shield Bond Connector 4460 
with LSM Clamp (2) 
G.  10-32 UNF Flange Nut (2) 
H.  Lubricant (1)
I.  Instruction Manual 78-0013-2695-4 (Not Shown)
A
B
C
D
E
F, G
H
1.2 
Kit Contents SLiC 530/533/733-2 Port-MSM 0.61 
Cable Entry Bracket 80-6113-8403-5
A.  Cable Addition Bracket Assembly (1) 
B.  Cap
C.  Multi-port Grommet (1) 
D.  Hose Clamp (1) 
E.  Pair Saver
F.  3M
 Scotchlok
 Shield Bond Connector 4460 
with LSM Clamp (2) 
G.  10-32 UNF Flange Nut (2) 
H.  Lubricant (1)
I.  Instruction Manual 78-8128-0289-6 (Not Shown)
A
B
C
D
E
F, G
H
2.0  Cable Preparations
2.1 
Per company practice, remove sufficient cable 
jacketing to allow for slack storage and splicing needs 
(approximately 5 feet).
2.2 
Trim central strength members on both cables 
approximately 3" (76 mm) from the end of the cable 
jacket.
Note: When using ribbon fiber cable, leave a minimum of 
2" (50 mm) of central tube.
2.3 
Insert cables into the multi-port grommet so that 
1.25" to 1.75" (32–45 mm) of cable jacketing is 
exposed past the inside edge of the grommet.
Note: A small amount of lubricant provided in the kit 
may be placed on the leading edge of the cable to ease 
installation into the grommet. 
Note: Place and tighten a cable tie around the grommet 
or you may also place a couple of wraps of Scotch
®
 
Linerless Rubber Splicing Tape 130C around cable to 
provide a better seal. 
Note: Carefully follow safety, health and environmental 
information given on product label or the Materials 
Safety Data Sheet for the lubricant.
1.25"–1.75" 
(32–45 mm)
3" (76 mm)