Transition Networks CGETF10XX-10X Benutzerhandbuch

Seite von 7
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications. 
Fiber Cable 
Bit Error Rate:  
<10-9
Single mode fiber (recommended):
9 µm 
Multimode fiber (recommended):
62.5/125 µm 
Multimode fiber (optional):  
100/140, 85/140, 50/125 µm 
CGETF1013-105
850 nm multimode
Fiber Optic Transmitter Power:
min: -10.0 dBm
max: -4.0 dBm
Fiber Optic Receiver Sensitivity:
min: -17.0 dBm
max: 0.0 dBm
Link Budget:
7.0 dB
CGETF1014-105
1310 nm single mode
Fiber-optic Transmitter Power:
min: -13.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -20.0 dBm
max: -3.0 dBm
Link Budget:
7.0 dB
CGETF1015-105
1310 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: -0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -20.0 dBm
max: -3.0 dBm
Link Budget:
15.0 dB
CGETF1017-105
1550 nm single mode
Fiber-optic Transmitter Power:
min: -3.0 dBm
max: +2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -23.0 dBm
max: -3.0 dBm
Link Budget:
20.0 dB
CGETF1018-105
850 nm multimode
Fiber Optic Transmitter Power:
min: -10.0 dBm
max: -4.0 dBm
Fiber Optic Receiver Sensitivity:
min: -17.0 dBm
max: 0.0 dBm
Link Budget:
7.0 dB
CGETF1024-105
1300 nm extended multimode
Fiber-optic Transmitter Power:
min: -10.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -17.0 dBm
max: -3.0 dBm
Link Budget:
7.0 dB
CGETF1029-105
1310nm TX / 1550nm RX single mode 
CGETF1029-106
1550nm TX / 1310nm RX single mode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -21.0 dBm
max: -3.0 dBm
Link Budget:
13.0 dB
CGETF1029-107
1310nm TX / 1550nm RX single mode 
CGETF1029-108
1550nm TX / 1310nm RX single mode
Fiber-optic Transmitter Power:
min: -3.0 dBm
max: +2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -23.0 dBm
max: -8.0 dBm
Link Budget:
20.0 dB
CGETF1035-105
1550 nm single mode
Fiber-optic Transmitter Power:
min: 0.0 dBm
max: +5.0 dBm
Fiber-optic Receiver Sensitivity:
min: -27.0 dBm
max: -3.0 dBm
Link Budget:
27.0 dB
8
CGETF10xx-10x
24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600    
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Cable Specifications 
-- Continued
Fiber Cable 
- Continued
CGETF1039-105
850 nm multimode
Fiber Optic Transmitter Power:
min: -9.0 dBm
max: -4.0 dBm
Fiber Optic Receiver Sensitivity:
min: -17.0 dBm
max: -17.0 dBm
Link Budget:
8.0 dB
Copper Cable 
(Category 5 -- minimum requirement)
• Gauge = 24 to 22 AWG; Attenuation = 22.0 dB /100m @ 100 MHz
• Straight-through  OR  crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a gigabit network.
• Use only dedicated wire pairs for the active pins; e.g., blue/white & white/blue,
orange/white & white/orange, etc.
• Do not use flat or silver satin wire.
Technical Specifications
For Transition Networks’ Model CGETF10xx-10x or equivalent
Standards:
IEEE 802.3ab™, IEEE 802.3 2000
Data Rate / Delay:
1000 Mbs/300 nsec
Dimensions:
3.4" x 0.87" x 4.8" (86mm x 22mm x 122mm)
Weight:
3 oz. (91 g) approximate
Power Consumption:
5.4W, 450mA @ 12VDC
Packet Size:
10 Kbytes (maximum)
MTBF
381,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,344,000 hours (Bellcore7 V5.0)
Operating Temp:
Tmar* 0°C  to 50°C (32°F to 122°F)*
Storage Temp:
-15°C  to 65°C (5°F to 149°F)
Humidity:
10% to 90%, non condensing 
Altitude:
0 to 10,000 feet
Warranty:
Lifetime
*Manufacturer’s rated ambient temperature.  “Tmra” range for this slide-in-module depends
on the physical characteristics and the installation configuration of the Transition Networks
PointSystem™ chassis in which this slide-in-module  will be installed.
The information contained in this user’s guide is subject to change. For the most up-to-date
information on the CGETF10xx-10x media converter, view the user’s guide on-line at:
www.transition.com.
CAUTION:  Visible and invisible laser radiation when open. Do not stare into beam or
view directly with optical instruments.
CAUTION:  Use of controls, adjustments or the performance of procedures other than
those specified herein may result in hazardous radiation exposure.
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-
825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.