Black Box AC216A-R2 Benutzerhandbuch

Seite von 30
AC211A-R2 & AC216A-R2 
APPENDIX A / ANNEXE A 
 
 
 
PAGE 29 
 
  COMMAND  RESPONSE 
COMMAND DESCRIPTION 
VALUE /VALEUR 
  COMMANDE  RÉPONSE  DESCRIPTION DE LA COMMANDE 
TYPE
MIN MAX
DESCRIPTION 
  STATUS COMMANDS / COMMANDES D'ÉTAT 
 
UNIT 
Measures unity in kHz. 
Rd 
0 65535  
 
IL ILD 
This command allows to calculate the 
input line frequency in Hz. 
Rd 
0 65535 Line frequency (in kHz) = (UNIT VALUE) ÷ 
(ILD VALUE). 
 
ID IFD 
This command allows to calculate the 
input frame frequency in Hz. 
Rd 
0 65535
Frame frequency (in Hz) = (Line frequency in 
Hz) 
÷ (IFD VALUE). 
 
IP 
IPS 
Input Sync. detection. 
Rd 
0 = not detected  
1 = Sync. detected. 
 
IH 
IHP 
Sign of the horizontal input Sync.  
Rd 
0 = negative 
1 = positive. 
 
IV 
IVP 
Sign of the vertical input Sync.  
Rd 
0 = negative 
1 = positive. 
 
IK 
IST 
Input Sync type detection. 
Rd 
0 3 
0 = H &V. 
2 = SOG. 
1 = Comp. (TTL). 
3 = Composite (ana) 
 
II 
IIN 
Interlaced signal detection. 
Rd 
0 = not interlaced  
1 = interlaced. 
 
IO 
IOO 
"Out of range" signal detection. 
Rd 
0 = In range  
1 = Out of range. 
 
IF 
IFA 
Standard input signal detection. 
Rd 
0 11 
 
XF 
REFF 
Standard of the synchronized input. 
Rd 
0 11 
0 = no signal. 
1 = not compatible. 
2 = NTSC (3.58/60).  3 = PAL (4.43/50). 
4 = SECAM (50Hz).  5 = B & W (50Hz). 
6 = B & W (60Hz). 
7 = YUV 50 Hz. 
8 = YUV @ 60 Hz. 
9 = RGB @ 50 Hz. 
10 = RGB @ 60 Hz.   11 = Computer 
 XT 
REFT 
Frame frequency of the synchronized 
input. 
Rd 
0  65535 Value in hundredth of Hz. 
 XA 
REFA 
Synchronized 
input. 
Rd 
0 = Internal rate 
1 = follow selected in. 
 ut 
TKEV 
Transition 
availability. 
Rd 
1 = New input ready to commute. 
 
NOTE: Rd = Read only command / Commande de lecture. 