Removal of the HF compression driver and LF driver – two-way cabinets 
The perforated steel loudspeaker grille is held in place by six M5 button head screws, 
three on each side of the cabinet (NuQ-8 illustrated here). Remove these grille retaining 
screws and set the grille aside for later re-assembly. 
 
 
Undo the screws holding the low frequency driver in place and carefully lift it out and 
away from the cabinet. Make a note of the driver polarity for later reconnection. 
Disconnect the cables from the drive unit and completely remove the driver from the 
cabinet being careful not to damage the cone or suspension. Do not place the driver near 
to any equipment or media that may be adversely affected by strong magnetism, e.g. 
CRT monitors or magnetic tape of any kind. 
Remove the horn/driver assembly by unscrewing the four screws holding the flange in 
place. Lift it out and away from the cabinet. The high frequency driver can now be 
disassembled from the HF horn. 
To reinstate the driver(s) simply reverse the above procedure, making sure you observe 
the correct polarity when reconnecting the cables back into the terminals of the drive 
units.