Whirlpool 8178023 Benutzerhandbuch

Seite von 10
7
DISPLAY
EXPLANATION
 PF  (Power Failure)
  If the household power goes off and the control was in RUN mode or 
  PAUSE mode, the electronic control board will display a power failure
  error code.
  To resume operation from where the last cycle was interrupted, press 
  the START keypad.
  To switch to STANDBY mode, press the STOP/CANCEL keypad.
  The dryer will not run if the exhaust temperature drops below 18˚F
  or exceeds 250˚F.
 E1
  When the thermistor circuit is open (>50K 
Ω), the error code E1 flashes
  in the display.
 E2
  When the thermistor circuit is shorted (<500 
Ω), the error code E2 
  flashes in the display.
  NOTE: During a cycle, if the error condition is detected, the control delays action 
  one (1) minute for the start of the cycle to allow temperatures to get into the 
  allowable range. During diagnostics, the error is displayed immediately. If the 
  START keypad is pressed, an invalid tone will sound, and the dryer will remain 
  in PROGRAM mode. The dryer will not start until the failed thermistor is replaced.
 E3   (Keyswitch or
  Flashes when there is a keyswitch or software mismatch. NOTE: This error code
Software  Mismatch)
  is displayed only in the diagnostics mode.
 (Thermistor Failure)
ERROR CODES
TEMPERATURE
RESISTANCE
˚F
K (1000) 
Ω
50
19.9
60
15.3
70
11.9
80
9.2
90
7.4
100
5.7
110
4.7
120
3.7
130
3.1
140
2.5
THERMISTOR RESISTANCE TEST