Gas Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
MGDB800V
Dryer dimensions
Select the route that will provide the straightest and 
most direct path outdoors.  
 
Plan the installation to use the fewest number of elbows 
and turns.  
 
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
W10347751B
9/2011
For closet installation, with a door, the minimum ventilation openings in the top  
and bottom of the door are required. Louvered doors with equivalent air ventilation  
openings are acceptable.
Do not use vent runs longer than specified in vent 
length chart.  
NOTE: Most installations require a minimum of 5" (127 mm) clearance 
behind dryer for exhaust vent with elbow. See “Venting Requirements.”
Vent system chart
Number of 
90° elbows
Type  
of vent
Box/louvered
hoods
Angled  
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
The Vent system chart provides venting requirements 
that will help achieve best drying performance.
NOTE: Bottom exhaust installations have a 90° turn 
inside the dryer. To determine maximum exhaust length, 
add one 90° turn to the chart.
Louvered Hood
Angled Hood
Box Hood
Acceptable Style:
Recommended Styles:
Dryer with extended back:
Dryer with flat back:
Recessed area
Side view - closet or confined area 
(Dryer with extended back)
Closet door with vents
Side view - closet or confined area
(Dryer with flat back)
* Required spacing
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with 
tested spacing of 0" (0 mm) clearance on sides and rear. 
Gas supply: This dryer is equipped for use with Natural gas. 
Dryer can be converted to L.P. gas. When rigid pipe is used 
it should be 1/2" IPS. When acceptable to the gas supplier 
and local codes, 3/8" approved tubing may be used for 
lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 
m), larger tubing should be used. Pipe-joint compounds 
resistant to the action of L.P. gas must be used. An 
individual manual shutoff valve must be installed within 6 
ft (1.8 m) of the dryer in accordance with the National Fuel 
Gas Code ANSI Z223.1. 
 
Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused 
electrical supply is required. A time-delay fuse or circuit 
breaker and a separate circuit are recommended. 
 
Water (Steam models only): The dryer must be connected 
to the cold water faucet using new inlet hoses. Do not use 
old hoses. Do not overtighten. Damage to the coupling can 
result.
Exhaust venting
Exhaust your dryer to the outside. 4" 
(102 mm) diameter vent is required. Rigid or flexible metal 
exhaust vent must be used. Do not use plastic or metal 
foil vet. Exhaust hood must be at least 12" (305 mm) from 
the ground or any object that may be in the path of the 
exhaust.
29"
(737 mm)
1"
(25 mm)
1"
(25 mm)
18"*
(457 mm)
14" max.*
(356 mm)
5"
(127 mm)
1"
(25 mm)
30"
(762 mm)
14" max.*
(356 mm)
5"
(127 mm)
1"
(25 mm)
28"
(711 mm)
3"*
(76 mm)
3"*
(76 mm)
48" 
2
*
(310 cm
2
)
24" 
2
*
(155 cm
2
)
30"
(762 mm)
22
1
/
4
"
(565 mm)
43
1
/
2
"
(783 mm)
28"
(711 mm)