4. Screw the legs into the leg holes by hand. Use a wrench to 
finish turning the legs until the diamond marking is no longer 
visible.
5. Place a carton corner post from dryer packaging under each 
of the 2 dryer back corners. Stand the dryer up. Slide the 
dryer on the corner posts until it is close to its final location. 
Leave enough room to connect the exhaust vent or gas line.
For mobile home use
Gas dryers must be securely fastened to the floor at the time of 
installation.
Mobile home installations require a Mobile Home Installation Kit. 
For more information, please call 1-800-4-MY-HOME
®
 
(1-800-469-4663).
Level Dryer
Check the levelness of the dryer. Check levelness first 
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. 
Use a wrench to adjust the legs up or down and check again for 
levelness.
Make Gas Connection
1. Remove the red cap from the gas pipe. 
2. Using a wrench to tighten, connect the gas supply to the 
dryer. Use pipe-joint compound on the threads of all non-
flared male fittings. If flexible metal tubing is used, be sure 
there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to the action of LP gas. Do not use 
TEFLON
®†
 tape.
A combination of pipe fittings must be used to connect the 
dryer to the existing gas line. Shown is a recommended 
connection. Your connection may be different, according to 
the supply line type, size and location.
3. Open the shutoff valve in the supply line. The valve is open 
when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 
dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Check that the vent is secured 
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible 
gas line.
4. Once the exhaust vent connection is made, remove the 
corner posts and cardboard.
A. Flared male fitting
B. Non-flared male fitting
A
B
®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A.
³⁄₈
" flexible gas connector
B.
³⁄₈
" dryer pipe 
C.
³⁄₈
" to 
³⁄₈
" pipe elbow
D.
³⁄₈
" pipe-to-flare adapter fitting
A. Closed valve
B. Open valve
A
B
C
D
A