Sears 9709 Benutzerhandbuch

Seite von 52
9
Dryer gas pipe
The gas pipe that comes out through the rear of your dryer 
has a 
³⁄₈" male pipe thread.
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height 
must be an additional 10" (25.4 cm) or 15.5" (39.4 cm) from the 
floor, depending on the pedestal model. For a garage 
installation, the gas pipe height must be an additional 
18" (46 cm) from the floor.
Venting Requirements
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible 
heavy metal vent.
Review Vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance.
If this is a new vent system 
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be 
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your 
dealer. For further information, please call 
1-800-4-MY-HOME
®
 (1-800-469-4663) or visit our website at 
www.sears.com.
Rigid metal vent
For best drying performance, rigid metal vents are 
recommended.
Rigid metal vent is recommended to avoid crushing and 
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for 
cleaning.
Flexible metal vent must be fully extended and supported 
when the dryer is in its final location. 
Remove excess flexible metal vent to avoid sagging and 
kinking that may result in reduced airflow and poor 
performance.
Do not install flexible metal vent in enclosed walls, ceilings or 
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Clamps
Use clamps to seal all joints. 
Exhaust vent must not be connected or secured with screws 
or other fastening devices that extend into the interior of the 
duct. Do not use duct tape.
A. ½" NPT gas supply line
B.
³⁄₈
" NPT dryer pipe
A
B
    *6¼"
(15.9 cm)
   1½"
(3.8 cm)
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
4" (10.2 cm) heavy metal exhaust vent
             Good
         Better
Clamp
4"
10.2 cm