READING ERROR CODES
1.  Press and hold the Select and Cancel buttons simultaneously for 6 seconds to reset control. The buzzer will sound 1 time. 
2.  Immediately after, rotate cycle selector knob 2 turns counter-clockwise to the third position from the top, and then  
 
press and hold the Select and Cancel buttons simultaneously for 6 seconds. The control will enter Field Test Mode, the  
 
buzzer will sound 3 times, and the digital display will alternate between “Fld” and the firmware revision number (ex. “r03”). 
3.  Rotate the cycle selector knob 2 turns counterclockwise. The error code will appear in the digit display. 
Troubleshoot problem by using chart below.  
To move on to the next code, press the Options button. 
To clear code, press the Select button. Code will be cleared when mode is exited. 
To exit this mode, simultaneously press and hold the Select and Cancel buttons for 6 seconds. 
Error Code 
Label 
Description 
Solution 
E10  
General EEPROM 
Fault
Problem with communication 
between EEPROM and the 
microprocessor.
Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.
E11  
Checksum Error  
Problem with communications or 
memory did not check, one has 
become corrupted.  
Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.
E12  
Non fatal R/W 
error  
Problem reading or writing to the 
memory or input/output.  
Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.
E24  
Control NTC Short 
Circuit
Control thermistor or its wiring is 
shorted.
Remove wires from control thermistor. Measure resistance of thermistor. If 
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 
10%), check wiring between thermistor and electronic control. If good, 
replace electronic control.
E25  
Control NTC Open 
Circuit
Control thermistor or its wiring is 
open.
Remove wires from control thermistor. Measure resistance of thermistor. If 
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (± 
10%), check wiring between thermistor and electronic control. If good, 
replace electronic control.
E4A  
Program Timeout 
Fault
The drying time has exceeded 
program time for that cycle.  
Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes. 
Position cycle selector to NORMAL, temperature selector to HIGH HEAT 
and touch START. Check for anything that would extend dry times such as: 
no heat, restricted vent, blower fan blade broken or loose, dryer installed in 
closet with solid door, or bad connection in moisture sensor bar circuit or 
dirty bars. If dryer operates normally but code returns, replace electronic 
control.
E5B  
Heater Fault (no 
heating)
Temperature reading of control 
thermistor has not changed in a 
certain amount of time.  
Position cycle selector to NORMAL, temperature selector to HIGH HEAT 
and touch START. Measure voltage across terminals on relay RL2 (heater 
relay) on electronic control. If meter reads 240V on electric models and 
120V on gas models, replace electronic control. If meter reads zero, remove 
power from dryer. Disconnect wire going to NO terminal on the relay RL2. 
Reconnect power and measure voltage drop between terminal COM on 
relay RL2 and neutral. If meter reads zero, wire between incoming line and 
relay RL2 is open. If meter reads 120V, check the rest of the heater circuit.  
E68  
Key (button) Struck 
Fault
One of the keys (buttons) is stuck 
closed (active).
Enter function test mode and perform key (button) test to determine which 
button is at fault. Carefully free the and perform the test again. If button is 
free but the key struck code still exists, replace electronic control.  
E8C  
Too many trips in a 
period of time.
The safety (high limit) thermostat 
has tripped too many times within 
a certain period of program time.  
Check for blocked lint filter, blocked exhaust, air leaks around air duct, 
broken blower fan blades, worn or loose drum seals, dryer installed in closet 
with solid doors or door seal not correctly seated.  
EAF  
Watch Dog Reset  
Microcontroller has been reset by 
internal Watchdog timer.
Clear code, exit mode and start dryer. If problem persists, replace electronic 
control.
NOTE: During normal operation, the display may show: 
 
LOC” - control lock is activated. 
 
PAU” - cycle has been interrupted.