IBM 4613 Benutzerhandbuch

Seite von 104
SurePOS 100 Technical Reference 
 
 
 
 
 
 
 
Page 25 of 104 
 
INDEX 28H: 
Read/write 
7 6 5 4 3 2 1 0 Function 
------------------------------------------------------------------- 
x x x x x x x 1 disable C/D driver 
x x x x x x x 0 enable C/D driver 
x x x x x x 1 x C/D pulse = 100 mS (recommended) 
x x x x x x 0 x C/D pulse = 50 mS 
x x x x x 0 x x C/D controlled by prt logic 
x x x x x 1 x x C/D controlled by ASIC 
 
Control register T 
Cash drawer open via ASIC 
INDEX 29H: 
Write only 
7 6 5 4 3 2 1 0 Function 
------------------------------------------------------------------- 
0 0 0 0 0 0 0 1 Pulse C/D circuit (open drawer) 
 
Control register U 
Cash drawer status 
INDEX 30H: 
Read/write 
7 6 5 4 3 2 1 0 Function 
------------------------------------------------------------------- 
x x x x x x 0 x IBM cash drawer connected 
x x x x x x 1 x IBM cash drawer not connected 
x x x x x 0 x x IBM cash drawer open 
x x x x x 1 x x IBM cash drawer closed