Panasonic 75/85/95 MXP Benutzerhandbuch

Seite von 315
TANDBERG Edge 75/85/95 MXP 
258 
 
Appendix 9: Connecting the System 
to the Switched 56 Network 
 
(Not available on all TANDBERG systems) 
 
Connecting the system to the Switched 56 network 
 
Using Telesync TS-256 SW56/ISDN adapter 
Connecting the system to the SW56 network using a Telesync Adapter is described below. There 
are different Telesync Adapters for different configurations of SW56 networks. The network types 
tested with the system are SW56 2Wire and 4Wire. 
 
Connecting 
Connect the system ISDN1 cable to the BRI S/T interface on the Telesync Adapter. Connect the 
two SW56 cables from the Telesync adapter Line 1 and Line 2 to the SW56 network. 
 
 
 
 
 
Configuration of the system 
Select network type to National ISDN. 
 
LINE 1 SETUP 
NUMBER1: 
NUMBER2: 
SPID1:  
SPID2: 
program with number from the first SW56 line 
program with number from the second SW56 line 
program with number from the first SW56 line 
Leave blank 
 
How to call 
It is important to use Restrict (56k). Select Restrict (56k) in Call Settings in the Call menu (select 
the field next to the phone book button in the call menu). A second number field will appear when 
ISDN is selected for Net within Call Settings and you choose bandwidth 128 kbps. Enter the 
second number in the call settings menu.