MATE SCREENS
STACKING MENU 
The STACK (stacking) section is used to program the stacking of the FX’s as well as which ‘Slave’ FX’s will stay ON at all times (won’t 
go into ‘Power Save’ mode) and in what order the slave FX’s will come ON (if they are in ‘Power Save’ mode).  An explanation of 
stacking can be found on pages 24-26 of this manual.   
 
ADV/FX/PAGE1-------- 
choose category: 
 
ADV  INV   CHGR  PG2 
                  
 
ADV/FX/PAGE2-------- 
choose category: 
 
PG1  GRID   GEN  PG3 
                  
 
ADV/FX/PAGE3-------- 
choose category: 
 
PG2  AUX  STACK  PG4 
            
 
ADV/FX/STACK-----P00 
Stack 1-2ph Master  
phase 
DOWN  INC  DEC  PORT 
 
  
ADV/FX/STACK-----P00 
power save level   0 
master adjust only 
DOWN  INC  DEC  PORT 
 
 
ADV/FX/STACK-----P00 
power save level   1 
slave adjust only 
DOWN  INC  DEC  PORT 
 
 
ADV/FX/STACK-------- 
  stacking setup 
     completed 
      TOP  ADV  MAIN 
 
 
 
Once the password has been correctly entered, the ADV - CHOOSE CATEGORY: screen is 
displayed.  Selecting <PG2> shows a second screen of categories.   
 
 
Selecting <PG3> shows a third screen of categories.   
 
 
Selecting <STACK> allows adjustment of the stacking set points and operation.   
 
 
The STACK PHASE screen sets the hierarchy of the FX’s.  If the system is to be stacked, a HUB 
must be included and the FX that is to be the MASTER must be plugged into port 1 of the HUB.  The 
default for every FX is ‘1-2ph Master’.  Pressing PORT will select the next port that an FX is plugged 
into.  When the port for the slave FX has been chosen, press INC to cycle through the slave options 
(Classic Slave, OB Slave L1, OB Slave L2, 3ph Master, and 3ph Slave). 
The POWER SAVE LEVEL MASTER ADJUST is used to set the number of FX SLAVE’s that will 
remain on under any load condition.  The value corresponds to the rank of the SLAVE.  For example, 
setting this value to 2 allows all slaves with POWER SAVE LEVEL SLAVE ADJUST ONLY values 2 
or less to stay on at all times.  Setting this number to a low value will result in fewer FX’s remaining 
on and will provide the highest system efficiency.     
The POWER SAVE LEVEL SLAVE ADJUST is used to set a slave FX’s priority for operation when 
the complete system is operating at medium to heavy loads.  By setting each of the slaves to a 
different number you can control the sequence that the slave FX’s are turned on by the master FX.   
 
Selecting TOP returns the user to the top of the ADV/FX/STACK menu section.  Selecting ADV 
returns you to the advanced screen to allow selection of another product connected to the MATE.  
Selecting MAIN returns the display to the MAIN screen.