Citizen iDP3210 Benutzerhandbuch

Seite von 73
iDP3210 User’s Manual
25
CITIZEN
6.2 Serial Interface
6.2.1 Specifications
(1) Data transfer system
:
Asynchronous
(2) Baud rates
150, 300, 600, 1200, 2400, 4800, 9600, 19200 bps (Selectable by user)
(3) Configuration of one word
Start bit
:
1 bit
Data bit
:
7 bits or 8 bits (Selectable by user))
Parity bit
:
Add/even or no parity
(Selectable by user)
Stop bit
:
1 bit or more
(4) Signal polarity
RS-232C
Mark
=
Logic " 1" (–3V to –12V)
Space
=
Logic " 0" (+3V to +12V)
(5) Receive data (RD signal)
RS-232C
Mark
=
1
Space
=
0
(6) Data receiving control (DTR signal)
RS-232C
Mark
:
Data transfer not available
Space
:
Data transfer available
(7) Data transmission control (TD signal)
DC1 code (11H) X-ON :
Data reception available
DC3 code (13H) X-OFF :
Data reception not available