Fujitsu C150-E049-02EN Benutzerhandbuch

Seite von 236
3-120
M3099GX/GH OEM Manual
Multiple READ (disconnect enabled)
This sequence is intended for system which scans one page document
dividing small quantity of data reading and saving to storage.
IDENTIFY
ARB
SEL
MO
CMD
Init
Init 
← 
Targ
READ(TL) ;M=0
VD>=TL
DI
Image Data(64KB*N)
Yes
No
TD<=WD
STS
MI
BF
GOOD
COMMAND COMPLETE
STS
MI
BF
CHECK CONDITION
COMMAND COMPLETE
Yes
No
Read End
VD>=64KB
MI
DISCONNECT
BF
VD>=TL-M
VD<64KB
ARB
Targ
RESEL
Targ 
 Init
MO
IDENTIFY
MI
SAVE DATA POINTER
MI
RESEL
ARB
Targ
Targ 
 Init
IDENTIFY
MO
DI
Image Data(TL-M)
TD+=TL
Yes
EOM=1
TD>=WD
Yes
Yes
Yes
BF
DISCONNECT
M=M+64KB*N
No
No
No
No
TD=0
See Note 1, 2.
#03.pm5
98.2.22, 1:34 PM