j.
Command>specific information bytes:   Bytes 8 to B 
On this scanner, this field is not supported and is fixed to X©00000000π.
k. Additional sense code, additional sense code qualifier:   Bytes C and D
A combination of these fields specifies detailed information about the error
reported in the sense key.  This scanner reports the following information: 
Sense
key
Additional
sense code
Additional
sense code
qualifier
Description
0
00
00
No> sense
2
00
00
Not ready
2
80
01
Interlock switch is opened
3
80
01
Jam
3
80
02
ADF cover open
3
80
03
Document chuter empty of paper
3
80
04
Detects job separation sheet 
(See Appendix A.5)
4
80
01
Blown fuse for FB motor
4
80
02
Blown fuse for heater
4
80
03
Blown lamp fuse
4
80
04
Blown fuse for ADF motor
4
80
05
Mechanical alarm
4
80
06
Optical alarm
4
44
00
Abnormal internal target
4
47
00
SCSI parity error
5
20
00
Invalid command
5
24
00
Invalid field in CDB
5
25
00
Unsupported logical unit
5
26
00
Invalid field in parameter list
5
2C
02
Wrong window combination
6
00
00
UNIT ATTENTION
B
43
00
Message error
B
80
01
Image transfer error