Panasonic AJ-SPX800E Benutzerhandbuch

Seite von 118
106
8-5-8
IRIS
8-6
MAIN OPERATION
8-6-1
BATTERY/P2CARD
The ____ in the Adjustable Range column indicates the preset
mode. 
Items/
Data Saved 
Adjustable 
Range 
Remarks 
A.IRIS LEVEL
000
 : 
050
 : 
100
Set the target value for auto iris. 
– C U F E
A.IRIS PEAK/
AVE
000
 : 
040
 : 
100
Determine the peak-to-standard ratio for the 
auto iris. 
A larger value sets the auto iris to respond to 
the peak in the IRIS detection window, while 
a smaller value sets it to respond to the 
average value in the window. 
– C U F E
A.IRIS MODE
NORM1
NORM2
CENTR
Select the auto iris detection window. 
NORM1:The window closer to the centre of 
the screen. 
NORM2:The window closer to bottom of the 
screen. 
CENTR: The spot window in the centre of the 
screen. 
– C U F E
S.IRIS LEVEL
000
 : 
080
 : 
100
Set the target value for the super iris. 
– C U F E
IRIS GAIN
CAM
LENS
Select which unit controls IRIS GAIN. 
<Note>
Lenses with an extender, such as
C2, C0.8 
sold before FUJINON DIGI POWER, 
perform IRIS compensation while enabling 
the extender. Therefore, if this setting is 
switched to CAM, the camera’s iris control 
will not operate properly. 
– C U F E
IRIS GAIN 
VALUE
01
 : 
08
 : 
20
Set the adjustable value for IRIS GAIN. This 
setting is effective when CAM is selected for 
IRIS GAIN. 
– C U F E
Items/
Data Saved 
Adjustable 
Range 
Remarks
BATTERY 
SELECT
PRO14
TRIM14
HYTRN50
HYTRN100
HYTRN120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Select the battery to use. Remaining 
capacity detection is also performed 
according to the selected battery. 
The selectable battery types change 
depending on the settings under [8-6-2 
BATTERY SETTING1] and [8-6-3 BATTERY 
SETTING2]. 
– C U F –
EXT DC IN 
SELECT
AC_ADPT
PRO14
TRIM14
HYTRN50
HYTRN100
HYTRN120
DIONIC90
DIONIC160
HP-90L
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NiCd14
NiCd13
NiCd12
TYPE A
TYPE B
Set the remaining capacity detection type 
when a battery is connected to the DC IN 
connector. Remaining capacity detection is 
also performed according to the selected 
battery type. 
The selectable battery types change 
depending on the settings under [8-6-2 
BATTERY SETTING1] and [8-6-3 BATTERY 
SETTING2]. 
<Note>
The % display is disabled even when a 
digital battery is connected to the DC IN 
connector. 
– C U F –
BATT NEAR 
END ALARM
ON
OFF
Select whether or not to set the alarm to 
beep for BATT NEAR END ALARM. 
– C U F –
BATT NEAR 
END CANCEL
ON
OFF
If set to ON, the warning tone and indication 
can be canceled by pressing the MODE 
CHECK button when BATT NEAR END 
ALARM is triggered. 
– C U F –
BATT END 
ALARM
ON
OFF
Select whether or not to set the alarm to 
beep for BATT END ALARM. 
– C U F –
BATT REMAIN 
FULL
100%
70%
Set the display content of the remaining 
battery capacity indicator bars in the display 
window when using a digital battery. 
100%:  Indicate FULL at 100% capacity. 
70%:  Indicate FULL at 70% capacity. 
– C U F –