Panasonic AJ-SPX800E Benutzerhandbuch

Seite von 118
109
8
8-6-3
BATTERY SETTING2
The ____ in the Adjustable Range column indicates the preset
mode.
Items/
Data Saved 
Adjustable 
Range 
Remarks 
NiCd14
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
NEAR END 11.0
 : 
13.6
 : 
15.0
Set the NEAR END voltage in 0.1 V steps. 
END
11.0
 : 
13.2
 : 
15.0
When MANUAL is selected in the menu 
above, set the END voltage in 0.1 V steps. 
– C U F –
NiCd13
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection.
NEAR END 11.0
 : 
12.7
 : 
15.0
Set the NEAR END voltage in 0.1 V steps. 
END
11.0
 : 
12.2
 : 
15.0
When MANUAL is selected in the menu 
above, set the END voltage in 0.1 V steps. 
– C U F –
NiCd12
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
NEAR END 11.0
 : 
11.5
 : 
15.0
Set the NEAR END voltage in 0.1 V steps. 
END
11.0
 : 
11.2
 : 
15.0
When MANUAL is selected in the menu 
above, set the END voltage in 0.1 V steps. 
– C U F –
TYPE A
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
FULL
12.0
 : 
15.0
 : 
17.0
Set the voltage to display the FULL 
indication in 0.1 V steps. 
NEAR END 11.0
 : 
13.6
 : 
15.0
Set the NEAR END voltage in 0.1 V steps. 
END
11.0
 : 
13.2
 : 
15.0
When MANUAL is selected in the menu 
above, set the END voltage in 0.1 V steps. 
– C U F –
Items/
Data Saved 
Adjustable 
Range 
Remarks 
TYPE B
_
Enable selection under BATTERY SELECT. 
_:
Enable selection. 
 • :
Disable selection. 
FULL
12.0
 : 
13.5
 : 
17.0
Set the voltage to display the FULL 
indication in 0.1 V steps. 
NEAR END 11.0
 : 
11.8
 : 
15.0
Set the NEAR END voltage in 0.1 V steps. 
END
11.0
 : 
11.1
 : 
15.0
When MANUAL is selected in the menu 
above, set the END voltage in 0.1 V steps. 
– C U F –