Panasonic AJ-HPX3100G Benutzerhandbuch

Seite von 208
68
Adjustments and Settings for Recording : Setting Time Data
The unit’s internal time code generator can be locked to an 
external generator. In addition, the external time code 
generator can be locked to the unit’s internal generator.
As the figure shows, connect both the reference video signal 
and reference time code.
For more information about the reference video signal and 
GENLOCK, see [Setting External Reference Signal and 
GENLOCK] (page 61).
Example 1: When locking onto an external signal
Example 2: When connecting a multiple number of units 
and using one of them as the reference unit
‹
Note
If you make a system with more than one unit, use the same 
settings for all cameras for input and output. When different 
settings are mixed, the image timing will not match. 
In the unit, there is a video signal delay in the camera, which 
is required or the process of converting video images taken 
with the image-shooting element from the progressive 
signals to the interlace signals. Since time is required for 
making the 2:3 pull-down from the 24P frame, there is a 
video signal delay in the camera. When recording from a 
device that can record images without a delay and the unit is 
connected in parallel, it is necessary to synchronize the time 
code. To set this timing,  set it in the TC VIDEO SYNCHRO 
item. The menu item TC VIDEO SYNCHRO is found in the 
<TC UB> screen on the MAIN OPERATION page.
Set by referring to the connection example.
Setting of the TC VIDEO SYNCHRO item
‹
Note
This setting is enabled during progressive shooting (when 
CAMERA MODE is 24P, 30P, 25P), and when the Scan Reverse 
function is operating. This setting is unnecessary during 
normal recording (when CAMERA MODE is 60i, 50i). 
Externally Locking the Time Code
Example of connections for external locking
GENLOCK IN
TC IN 
SDI IN
Reference time 
code
Reference video 
signal
TC IN
TC OUT 
TC IN
TC OUT 
TC OUT 
GENLOCK IN
SDI IN
GENLOCK IN
SDI IN
Reference unit
To the next camera
Reference video signal
Reference video signal
Reference video signal
or
or
Item
Variable 
range
Remarks
TC VIDEO 
SYNCHRO
0
1
2
3
For setting to correct the time code 
according to the delay of video signals.
0: Do not correct.
1: To delay the time code to be input
according to the timing of the
video images.
2: To forward the time code to be
output according to the timing of
the video images.
3: To delay the time code to be input
and forward the time code to be
output, respectively, according to
the timing of the video images.
AJ-HPX3100G(VQT3A79)_E.book  68 ページ  2010年9月17日 金曜日 午後9時21分