Panasonic AJ-HDX900 Benutzerhandbuch

Seite von 134
124
Chapter 7  Menu description tables 
(continued)
7-6-6 INITIALIZE
For details, refer to “4-10 Set data handling.”
Item
Variable
range
Remarks
READ FACTORY
DATA
For returning the state of the unit to factory
settings.
Data returned to factory settings
O
User data
O
Scene file
Data not returned to factory settings
O
Lens file
O
Black shading
O
White shading
WRITE USER
DATA
The menu data that is inherent to the user
are saved in user data memory on the unit.
7-7-2 DIAGNOSTIC
FPGA (TG)
For displaying the version of the FPGA for
the CCD drive.
Item
Variable
range
Remarks
CAMSOFT(IN)
For displaying the version of the software
used for the flash memory incorporated in
the microcomputer.
CAMSOFT(OUT)
For displaying the version of the software
used for the externally connected flash
memory.
FONT ROM
For displaying the version of the font used
for the characters.
CAM TABLE
For displaying the version of the tables.
FPGA (CHAR)
For displaying the version of the FPGA for
characters.
FPGA (D/C)
For displaying the version of the FPGA for
down converters.
FPGA (FM)
For displaying the version of the FPGA for
frame memories.
7-7 MAINTENANCE
7-7-1 SYSTEM CHECK
Item
Variable
range
Remarks
COLOR CHECK
ON
OFF
For checking whether the camera unit
operates properly.
ON:
The signal level of RGB near the center of
the screen is displayed in the viewfinder.
It indicates with numeric values that the
respective RGB signals are properly
transmitted from the optical system to the
digital system and processed.
OFF:
Not display
7-7-3 LENS ADJ
Item
Variable
range
Remarks
F2.8 ADJ
ON
OFF
The iris is set to f/2.8 only when ON is set for
this item.
F16 ADJ
ON
OFF
The iris is set to f/16 only when ON is set for
this item.
The underlining in the variable range column indicates the setting in the preset
mode.