Panasonic AG-HPX600P Benutzerhandbuch

Seite von 178
– 173 –
Chapter 12 Specification — Details of the connector signals
Details of the connector signals
DC IN
1
GND
2
NC
3
NC
4
+
12 V
Panasonic Parts No: K1AA104H0038
Manufacturer Parts No: HA16RX-4P (SW1) (76) (Hirose Electric Co.)
@
@
NOTE
 tMake sure that the polarity of the external power supply is correct.
FRONT MIC IN
1
GND
2
AUDIO IN (H)
3
AUDIO IN (C)
Panasonic Parts No: K1AY103A0001
Manufacturer Parts No: HA16PRM-3SG (72) (Hirose Electric Co.)
AUDIO IN
1
GND
2
AUDIO IN (H)
3
AUDIO IN (C)
Panasonic Parts No: K1AY103A0001
Manufacturer Parts No: HA16PRM-3SG (72) (Hirose Electric Co.)
REMOTE
1
CAM DATA (H)
2
CAM DATA (C)
3
CAM CONT (H)
4
CAM CONT (C)
5
R/C ON
6
R/C VIDEO OUT
7
R/C VIDEO GND
8
NC
9
UNREG+12 V (max. 0.6 A)
10
GND
Panasonic Parts No: K1AY110JA001
Manufacturer Parts No: HR10A-10R-10SC (71) (Hirose Electric Co.)
DC OUT
1
GND
2
R TALLY (open collector)
3
REC SW
4
UNREG+12 V (max. 1.5 A)
Panasonic Parts No: K1AY104J0001
Manufacturer Parts No: HR10A-7R-4SC (73) (Hirose Electric Co.)
VF
1
UNREG-12V
DC 12 V power (AJ-HVF21KG: approx. 0.35 A)
2
UNREG-12V
DC 12 V power
3
A9.0V
DC 9 V power (not used)
4
VF-P
B
-GND
Viewfinder P
B
 signal GND
5
VF-P
R
-GND
Viewfinder P
R
 signal GND
6
VF-Y
Viewfinder Y signal output
7
VF-Y-GND
Viewfinder Y signal GND
8
VF-CLK
Serial data clock pulse signal
9
VF-WR
Pulse signal for serial/parallel conversion data 
reading
10
VF-DATA
Serial data signal for serial/parallel conversion
11
UNREG-GND
GND
12
ZEBRA-SW
Zebra signal ON/OFF
13
PEAKING
Peaking control (not used)
14
SPARE
Spare (not used)
15
VF-P
R
Viewfinder P
R
 signal output
16
VF-P
B
Viewfinder P
B
 signal output
17
MARKER-SW
Marker ON/OFF (not used)
18
FRONT-VR
F.AUDIO LEVEL adjustment (not used)
19
VR-GND
F.AUDIO LEVEL GND (not used)
20
UNREG-GND
GND
Panasonic Parts No: K1AB120H0001
Manufacturer Parts No: HR12-14RA-20SC (Hirose Electric Co.)
@
@
NOTE
 tEnsure that the total current from the DC OUT, REMOTE, VF, and 
LENS terminals does not exceed 2.5 A.