5. «CAMERA: ON, OFF, CABLE OPEN»
indicator lights
• ON:
Normally and permanently lit, this light 
indicates that the camera is powered.
This indicator light when flashing indica-
tes excessive consumption at the camera.  
The current in the triaxial cable is then 
between 3 A and 3.3 A.  Above 3.3 A, the 
Channel Control Unit power supply cuts 
out.  rearming is obtained automatically 4 
times.  If the overload persists, the cut-out 
becomes permanent.  An equipment 
on/off is then required to start the equip-
ment operating again.
• OFF:
This permanently lit indicator light indica-
tes that the camera power is off.
When flashing, this indicator light indica-
tes that the camera consumption is exces-
sively low.  The current in the triaxial 
cable is then between 0.1 A and 0.4 A.
• CABLE OPEN: 
This normally extinguished indicator light 
indicates that the triaxial cable is not con-
nected to the camera or to the back panel 
of the Channel Control Unit.
6. «ON AIR» indicator light
When lit, this light indicates that the equip-
ment is switched to the antenna («ON
AIR1»).
7. «MAINS» switch
The equipment master on/off switch: 
• «I»: The equipment is operating.
• «O»: The equipment is not operating.