Sony F35 Benutzerhandbuch

Seite von 142
126
About Metadata
  
A
ppe
ndix
e
s
Warning/Error Messages
If battery power is low or a problem occurs at power on or 
during operation, a warning is given by an indicator 
flashing or various alarm indications.
Viewfinder screen
Subdisplay
RUN 
indicator
Meaning
Basic status 
display (page 48)
Message
BATT 12 V flashing
BATT 12 V flashing Flashing
Voltage of the 12 V power becomes low, 
reaching the specified NEAR END value.
BATT 12 V quick 
flashing
BATT 12 V quick 
flashing
Quick 
flashing
Voltage of the 12 V power becomes too 
low, reaching the specified END value.
BATT 24 V flashing
BATT 24 V flashing Flashing
Voltage of the 24 V power becomes low, 
reaching the specified NEAR END value.
BATT 24 V quick 
flashing
BATT 24 V quick 
flashing
Quick 
flashing
Voltage of the 24 V power becomes too 
low, reaching the specified END value.
TEMPERATURE CARE
Temperature inside the camera raises.
TEMP WARNING/FAN 
MAX
Temperature inside the camera raises to 
the limit. FAN MODE is forcibly set to MAX.
SHUTDOWN CAMERA/
FAN MAX
The camera must be turned off for safety.
FAN MODE is forcibly set to MAX.
OHB/SIDE FAN NG!
The fan near the CCD or the fan near the 
side panel stops.
PS FAN NG!
The fan near the power unit stops.
CAM?
OHB NG!
Abnormality of the CCD unit
CAM?
AD BOARD NG!
Abnormality of the AD board
CAM?
DPR BOARD NG!
Abnormality of the DPR board
CAM?
VDA BOARD NG!
Abnormality of the VDA board
CAM?
TR BOARD NG!
Abnormality of the TR board
CAM?
AT BOARD NG!
Abnormality of the AT board
IF BOX NG!
Abnormality of the interface box
OPT CA NG!
Abnormality of the CA-F101
UNKNOWN RECORDER
An unknown recorder is connected.
VTR ALARM
Alarm occurs at the SRW-1.
VTR WARNING
Warning occurs at the SRW-1.
LASER SHUTDOWN!
The laser-module protection circuit has 
been activated with the CA-F101 mounted.
For details, refer to the Operation Manual 
of the CA-F101.