Lucent Technologies 555-670-111 Benutzerhandbuch

Seite von 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Programming Procedures 
3-17
Basic System Operating Conditions 
3
Set System Time
3
NOTES:
The System Time feature allows you to set the time that appears on 
MLX, ETR, and MLS display telephones and on SMDR reports.
If you are planning to use the SMDR feature, make sure the system time 
is set accurately. If you change the system time while the system is in 
Night Service mode, Night Service is deactivated and must be manually 
reactivated. If you have installed applications such as MERLIN LEGEND 
Mail or Intuity AUDIX, you may need to set the time in the applications 
software whenever you reset the system time.
In Release 6.0 and later systems, where a MERLIN LEGEND 
Communications System is networked in a private network with one or 
more MERLIN LEGEND Communications Systems or with one or more 
DEFINITY Communications Systems, SMDR reports may report 
outgoing calls using more than one call record (especially for tandem 
calls), depending upon how SMDR is programmed and how calls are 
routed. Therefore, ensure that the system date and time are set 
accurately on each system that carries these calls. When you examine 
records for network calls, you may need to be aware of time zone 
differences among different system locations.
Summary: Set System Time
3
Programmable by 
System Manager
Mode 
All
Idle Condition 
Not Required
Planning Form 
1, System Planning
Factory Setting 
0000
Valid Entries 
0000 to 2359
Inspect 
No
Copy Option 
No
Console Procedure 
System
Time
Drop
Dial current time (0000–
2359)
Enter
Exit
 
PC Procedure 
7
 +
2I
Type current time (0000–
2359)