Entry/Exit Delays 
General Information 
Your system has installer-programmed time delays, known as exit delay and 
entry delay. Whenever you arm your system, exit delay gives you time to 
leave through the designated exit door without setting off an alarm. Exit 
delay begins immediately after entering any arming command, and applies to 
all modes of arming protection. If programmed, a slow beeping will sound 
throughout the exit delay period. 
Entry Delay gives you time to disarm the system when you reenter through 
the designated entrance door. But the system must be disarmed before the 
entry delay period ends, or an alarm will occur. The keypad will beep during 
the entry delay period, reminding you to disarm the system. You can also 
arm the system with no entry delay at all by using either INSTANT or 
MAXIMUM arming modes. These modes provide greater security while on 
the premises or while away for extended periods of time. See your installer 
for your delay times. 
 
As a requirement of SIA-CP-01, Entry Delay is defaulted to a delay of 30 
seconds and Exit Delay is defaulted to a delay of 60 seconds.  
As a requirement of SIA-CP-01, an Exit Delay Reset is designed to allow a 
user to re-enter the premises to retrieve a forgotten item without triggering 
an alarm. This feature may only be activated once after arming.  
If enabled, when the panel is armed, the normal exit delay begins.  After the 
user exits, closes the door and then re-enters the premises, the exit delay 
time is reset to the programmed value. 
As a requirement of SIA-CP-01, there is a communicator delay of 30 seconds 
in this control panel. This delay will prevent a report to the central station if 
the control panel is disarmed within 30 seconds after an intrusion alarm is 
triggered. This delay can be removed, or it can be increased up to 45 seconds 
at the option of the user by consulting with the Installer. Note that fire-type 
alarms are normally reported without delay.