Event Log Procedures 
General Information 
The system has the ability to record various events in a history log wherein each event is 
recorded in one of five categories (listed below), with the time and date of its occurrence. The 
Event Log holds up to 1000 events, with the oldest event being replaced by the logging of any 
new event after the log is full. Using an alpha keypad, the Event Log can be viewed one 
category at a time, or can display all events, regardless of category (ALL EVENT LOG). The 
system also allows selection of displaying the COMPLETE log, or only those events occurring 
since the last installer service (RECENT). In addition, events in the other partitions can be 
viewed by users authorized to access those partitions. Note that events are displayed in 
chronological order, from most recent to oldest. 
To Display the Event Log 
1.  Enter CODE +   #   + [6] + [0] 
2.  Select the display mode. 
RECENT: Displays only those events occurring since last Event Log Clear command was 
executed. 
COMPLETE: Displays complete event log (up to 1000 events). 
Press the desired key, 0 or 1. 
ENTER 0 = RECENT 
1 = COMPLETE 
3.  Select the partition, 0-8. 
Enter the partition number for the partition whose events are to be displayed. 
Entering 0 (NO) will display all partitions' events. 
SCAN LOG BY PART 
0 = NO 1-8 = PART# 
4.  Use the [3] & [1] keys (for next and previous categories respectively) to display  the 
categories of events. 
Press [8] to select a category and display the first event. Press [8] again for each 
subsequent event. 
Shows burglary alarm occurred in zone 3 (C003) of partition 1 (P1), at 12:02AM on 
January 1. 
P1 01/01  12:02AM 
BURGLARY C003 
Typical 
Event Log 
Display