Fire Alarm System 
Your fire alarm system (if installed) is on 24 hours a day, providing continuous 
protection.  In the event of an emergency, the smoke and heat detectors automatically 
send signals to your Control, triggering a loud interrupting sound from the keypad 
and the optional exterior sounders. FIRE appears at your keypad and remains on 
until you silence the alarm. 
NOTES:  
•  All smoke detectors must be tested monthly by pressing the TEST button located on 
the detector. Be aware that your keypad(s) and local siren(s) will activate (enter 
your 4-digit code + [Off] to silence). If your system is monitored by a central station 
you must first call the central station to advise them that a test is in progress. If the 
TEST button does not cause the detector to activate it must be replaced 
immediately. 
•  Ask your installer if your system is programmed for fire alarm verification, which 
can help reduce false alarms from smoke detectors. 
In Case Of Fire Alarm 
1.  Should you become aware of a fire emergency before your detectors sense the 
problem, go to your nearest keypad and manually initiate an alarm by pressing 
the panic key assigned as FIRE emergency (if programmed by the installer) and 
hold down for at least 2 seconds. 
2.  Evacuate all occupants from the premises. 
3.  If flames and/or smoke are present, leave the premises and notify your local Fire 
Department immediately. 
4.  If no flames or smoke are apparent, investigate the cause of the alarm.  The 
descriptor of the zone(s) in alarm appears at the keypad. 
Silencing a Fire Alarm 
1.  Silence the alarm by entering your code and pressing the OFF key.  To clear the 
display, enter your code and press the OFF key again 
2.  If the keypad does not indicate a READY condition after the second OFF 
sequence, press the READY key to display the faulted zone(s).  Be sure to check 
that smoke detectors are not responding to smoke or heat producing objects in 
their vicinity.  Should this be the case, eliminate the source of heat or smoke. 
3.  If this does not remedy the problem, there may still be smoke in the detector.  
Clear it by fanning the detector for about 30 seconds. 
4.  You can clear the display by entering your code + the OFF key.