Honeywell VISTA-15PSIA Benutzerhandbuch
– 51 –
Summary of Audible/Visual Notifications
Fixed-Word Display Keypads
SOUND CAUSE
DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
INTERRUPTED*
Keypad & Ext.
FIRE ALARM
FIRE
is displayed; zone number of zone in
alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be
displayed.
manually activated, zone number 95 will be
displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
CONTINUOUS*
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM
EMERGENCY ALARM
ALARM
is displayed. Zone number of zone
in alarm is also displayed.
ONE SHORT
BEEP
(not repeated)
Keypad only
BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
a. READY indicator light comes on.
b. Number of the open protection zone
b. Number of the open protection zone
displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS is displayed.
each zone displayed). Subsequently,
BYPASS is displayed.
ONE SHORT
BEEP
(about every 30
secs)
Keypad only
BEEP
(about every 30
secs)
Keypad only
a. SYSTEM IS IN TEST MODE
b. LOW BATTERY AT A
b. LOW BATTERY AT A
TRANSMITTER
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
b. BAT displayed with zone number of
transmitter.
c. No special display.
TWO SHORT
BEEPS
Keypad only
BEEPS
Keypad only
ARM AWAY or MAXIMUM
AWAY is displayed. Red ARMED indicator is
lit.
lit.
THREE SHORT
BEEPS
Keypad only
BEEPS
Keypad only
a. ARM STAY, NIGHT-STAY,
INSTANT
b. ZONE OPENED WITH
SYSTEM IN CHIME MODE.
a. STAY or INSTANT is displayed. Red
ARMED indicator is lit.
b. CHIME displayed; zone number of open
protection zone will be displayed if the [
✱]
key is pressed.
RAPID
BEEPING
Keypad only
BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
d. EXT. SOUNDER WIRING
FAIL
e. LAST 10 SEC of EXIT DELAY
a. CHECK
displayed. Zone number of
troubled protection zone is displayed.
b. FIRE or ALARM is displayed; zone
number of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70
is displayed.
e. No special display.
SLOW
BEEPING
Keypad only
BEEPING
Keypad only
a. EXIT DELAY WARNING
b. ENTRY DELAY WARNING
b. ENTRY DELAY WARNING
a. AWAY is displayed.
b. Exceeding the entry delay time without
b. Exceeding the entry delay time without
disarming causes alarm.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.