DMP Electronics Command Processor Panel Benutzerhandbuch

Seite von 26
4
XR10 Programming Guide
2841 E. Industrial Drive  Springfield, MO  65802-6310  800-641-4282
2 - INITIALIZATION
2.1
INITIALIZATION
This function allows you to set the panel's user codes and Programmer selections back to
factory defaults before programming the panel for the first time or a new installation.
After you select YES to clear a section of memory, the panel asks if you are sure you want to
clear the memory. This is a safeguard against accidently erasing the programming. No
memory is cleared from the programming until you answer yes to the SURE?  YES  NO
prompt.
A description of each selection follows:
2.2
CLEAR ALL CODES
YES clears the panel's user code memory and assigns the Master user code number 99 to
user number 12.
2.3
SET TO FACTORY DEFAULTS
YES sets the panel's Programmer selections back to factory defaults and clears any
information stored in Display Events memory.
3.1
COMMUNICATION
This section allows you to configure the communication settings for the XR10 panel. After
choosing the Communication type, continue through the remaining options.
3.2
COMMUNICATION TYPE
Specifies the communication method the panel uses to contact the receiver. Press any
SELECT key to display the following communication options:
NONE - For local systems. Selecting this ends Communication programming.
DD - Digital Dialer communication to DMP SCS-1 or SCS-105 Receivers.
4-2 - 4-2 communication to non-DMP receivers.
3.3
ACCOUNT NUMBER
Enter the account number sent to the receiver.
DD - The range of account numbers for Digital Dialer is 1 to 65,535. For account numbers of
four digits or less, you do not have to enter leading zeros. The panel automatically right
justifies the account number.
4-2 - The range of account numbers using 4-2 communication is 1 to 9999.
3.4
TRANSMIT DELAY
Enter the length of time the panel waits before sending burglary alarm reports to the receiver.
The available range is 10 to 60 seconds in ten second increments. Alarm bells and relay
outputs are not delayed during this period. Burglary Type output in section 7.4B must be
programmed for Steady output.
If the area where the alarm occurred is disarmed during the Transmit Delay, only an Abort
Report is sent. Abort Reports in section 5.3 must be set to YES.
Enter zero to disable Transmit Delay.
3.5
DTMF
YES enables tone dialing. NO enables rotary dialing.
      INITIALIZATION
CODES?     NO    YES
SURE?       YES     NO
SURE?        YES    NO
DEFAULTS? NO  YES
3 - COMMUNICATION
COMM TYPE:  NONE
COMMUNICATION
XMIT DELAY:      0
 NONE  DD  4-2
ACCOUNT NO:12 3 4 5
DTMF                  YES