DSCover Satellite Products PC1555MX Benutzerhandbuch

Seite von 52
24
If you enable the WLS Key Does Not Use Access Codes
option, the disarm button will  work  on  wireless  keys  which
have not been assigned access codes. Wireless keys can
only be assigned access codes when used with PC5132 v3.0
or higher. 
To prevent disarming by wireless keys which don’t have
access codes, disable this option. (Please see your PC5132
manual for more information on programming wireless keys.)
NOTE:   This option must be enabled when using a PC5132
v2.1 or earlier. 
Quick Arm Enable . . . . . . . . . . . . . . . . . . . . Section [015]: [4]
Quick Exit Enable  . . . . . . . . . . . . . . . . . . . . Section [015]: [3]
Arm/Disarm Bell Squawk. . . . . . . . . . . . . . . Section [014]: [1]
Squawk on Away Arm/Disarm Only. . . . . . . Section [017]: [8]
Closing Confirmation . . . . . . . . . . . . . . . . . . Section [381]: [4]
Opening After Alarm Keypad Ringback . . . Section [381]: [1]
Opening After Alarm Bell Ringback  . . . . . . Section [381]: [2]
Bypass Status Displayed While Armed. . . . Section [016]: [7]
Unident. Wkey Disarm Enabled  . . . . . . . . . Section [017]: [1]
5.18 Entry/Exit Delay Options
Two different Entry Delays can be programmed: the first entry
delay will be enabled for Delay 1 type zones and the second
for Delay 2 type zones. Only one Exit Delay can be pro-
grammed.
NOTE: When the panel is armed, the entry delay will follow the 
entry delay time programmed for the delay zone which is vio-
lated first.
Users can restart the exit delay by pressing the Away key
while it is counting down. The system will not log the user who
re-started the exit delay, unless the Quick Arming Disabled/
Function Keys Require Code
 option is turned on (Section
[015], Option [4]).
NOTE:  If the system has been Stay armed or armed with no
entry delay ([*][9]) pressing the Away key will not start an exit
delay.
Upon arming, the panel will begin the exit delay. If the Audible
Exit Delay with Urgency
 option is enabled, the keypad will
beep at one second intervals until the exit delay expires. The
keypad will beep rapidly for the last 10 seconds of exit delay
to warn the user that the system is about to arm. If this option
is disabled, the keypad will not beep during the exit delay.
The Audible Exit Fault, as explained in Section 3.1, will notify
the user if they failed to secure the premises upon arming.
This option can be enabled or disabled according to the
user’s needs.
For commercial applications, the Bell Squawk on Exit Delay
option may be enabled. The panel will squawk the alarm out-
put once every second when the exit delay is initiated and
three times per second for the last 10 seconds until the exit
delay expires.
Upon entry, if a Delay type zone is violated, the panel will
begin the entry delay. The keypad will emit a steady tone. The
keypad will pulse the keypad sounder during the last 10 sec-
onds to warn the user the system is about to go into alarm. If
there was an alarm during the armed period, the keypad will
pulse for the entire entry delay to warn the user of the previous
alarm.
For commercial applications Bell Squawk on Entry Delay
may be enabled. The panel will squawk the alarm output once
every second until the entry delay expires or the system is dis-
armed. 
If the Bell Squawk During Auto Arm option is enabled, the
bell will squawk once every 10 seconds for one minute during
the Auto-arm pre-alert. This will notify anyone on the premises
that the system is being armed.
If the Exit Delay Termination option is enabled, the panel will
monitor the Delay 1 zones during exit delay. During the exit
delay, if a Delay 1 type zone is violated and then secured, the
exit delay will be terminated and the panel will be armed
immediately.
Entry Delay 1 and 2 (System Times). . . . . . . . .  Section [005]
Exit Delay (System Times)  . . . . . . . . . . . . . . . .  Section [005]
Audible Exit Delay with Urgency  . . . . . . . . Section [014]: [6]
Audible Exit Fault Enabled/ Disabled . . . . . Section [013]: [6]
Bell Squawk Options. . . . . . . . . . . . . .  Section [014]: [2] - [4]
Exit Delay Termination. . . . . . . . . . . . . . . . . Section [014]: [7]
5.19 Swinger Shutdown
The swinger shutdown feature is designed to prevent a “run-
away” communicator from tying up the central station. After
the panel has communicated the programmed number of
transmissions for an event, it will no longer report that event
until the swinger shutdown is reset. Different swinger shut-
down levels can be set for zone alarms, zone tampers and
maintenance signals.
By default, each Swinger Shutdown limit is set to [003]. The
panel will not send more than three signals for each zone until
the swinger shutdown is reset.
The Bell output will not be activated for alarms on zones that
have exceeded the limit of alarms set in the Swinger Shut-
down counter.
Swinger shutdown will be reset every day at midnight or when
the panel is armed. Once reset, the panel will again communi-
cate normally.
Swinger Shutdown  . . . . . . . . . . . . . . . . . . . . . .  Section [370]  
5.20 Event Buffer
The panel will store the last 128 events which occurred on the
system. The Event Buffer will contain the name, time and
date of each event, along with the zone number, access code
number or any other information pertaining to the event.
If the Event Buffer Follows Swinger Shutdown option is
enabled, the event buffer will not store events after the
Swinger Shutdown level has been reached. This will prevent
the panel from overwriting the entire buffer if a problem exists.
The event buffer can be viewed in three different ways: from
an LCD keypad (see “[*][6] User Functions” on page 10)
printed on-site using the PC5400 printer module, or it can be
uploaded using DLS software.
Event Buffer Follows 
Swinger Shutdown  . . . . . . . . . . . . . . . . . . . Section [013]: [7]
5.21 Keypad Lockout Options
The panel can be programmed to “lock out” keypads if a
series of incorrect access codes are entered. Once the Num-
ber of Invalid Codes Before Lockout
 limit has been reached,
the panel will lock out all keypads for the Lockout Duration
and log the event to the event buffer. For the duration of the
lockout, the panel will sound an error tone when any key is
pressed.
NOTE:  The Invalid Code Counter will be reset every hour.
WWW.DIYALARMFORUM.COM