DSCover Satellite Products PC1555MX Benutzerhandbuch
40
[381] Second Communicator Option Code
Default Option
ON
OFF
Section
Page
#
OFF
I_______I
1
Open After Alarm Kypd Ringback enabled
Open After Alrm Kypd Ringback disabled
OFF
I_______I
2
Open After Alarm Bell Ringback enabled
Open After Alrm Bell Ringback disabled
OFF
I_______I
3
SIA Sends Programmed Rep. Codes
SIA Sends Automatic Rep. Codes
OFF
I_______I
4
Closing Confirmation Enabled
Closing Confirmation Disabled
ON
I_______I
5
Talk/Listen (PC5928) on phone lines 1/3
No Talk/Listen (PC5928) on phone lines 1/3 5.7
OFF
I_______I
6
Talk/Listen (PC5928) on phone line 2
No Talk/Listen (PC5928) on phone line 2
ON
I_______I
7
Contact ID Uses Programmed Rep. Codes
Contact ID Uses Automatic Rep. Codes
OFF
I_______I
8
For future use
—
[390] LINKS Preamble (First Telephone Number)
Default: FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
Default: FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
[392] LINKS Preamble (Third Telephone Number)
Default: FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
[393] LINKS Special Function Preamble (All Telephone Numbers)
Default: FFFFFF
I_______I_______I_______I_______I_______I_______I
(Program all unused digits with Hex F)
•Enter [*][2][*] (HEX B) to dial [*]
• Enter [*][3][*] (HEX C) to dial [#]
Downloading Options
[401] First Downloading Option Code
Default Option
ON
Off
OFF
I_______I
1
Answering machine/double call enabledAnswering machine/double call disabled
ON
I_______I
2
User Can Enable DLS Window
User Cannot Enable DLS Window
OFF
I_______I
3
Call-Back
Enabled
Call-Back
Disabled
OFF
I_______I
4
User-initiated call-up enabled
User-initiated call-up disabled
OFF
I_______I
5-8
For future use
[402] Downloading Computer’s Telephone Number (32 Digits)
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
[403] Downloading Access Code
Default: 5008
I_______I_______I_______I_______I
Enter 4 HEX digits
[404] Panel Identification Code
Default: 5008
I_______I_______I_______I_______I
Enter 4 HEX digits
[405] Answering Machine Double-call Timer
Default: 060
I_______I_______I_______I
(Valid entries are 001-255 seconds)
Default: 000
I_______I_______I_______I
(Valid entries are 000-255 rings)
[490] LINKS Preamble (Downloading Telephone Number)
Default: FFFF
I_______I_______I_______I_______I
(Program all unused digits with Hex F)
[499] [Installer’s Code] [499] Initiate PC-Link (Local Downloading)
WWW.DIYALARMFORUM.COM