DSCover Satellite Products PC1555MX Benutzerhandbuch

Seite von 52
46
[67] Fifth User Display Mask
Default Option 
ON
OFF
OFF
I_______I
   
1
Thermostat CTRL Prompt ON
Thermostat CTRL Prompt OFF
OFF
I_______I
   
2
Temperature Setting Prompt ON
Temperature Setting Prompt OFF
OFF
I_______I
   
3
Occupancy Mode Prompt ON
Occupancy Mode Prompt OFF
OFF
I_______I
   
4
Thermostat Mode Prompt ON
Thermostat Mode Prompt OFF
OFF
I_______I
   
5
Fan Control Prompt ON
Fan Control Prompt OFF
OFF
I_______I
   
6
For Keypad View Prompt ON
For Keypad View Prompt OFF
OFF
I_______I
   
7-8
For future use
[68] Sixth User Display Mask
Default Option 
ON
OFF
OFF
I_______I
   
1
Occupancy Mode Auxiliary Prompt ON
Occupancy Mode Auxiliary Prompt OFF
OFF
I_______I
   
2
Occupancy Mode Day Prompt ON
Occupancy Mode Day Prompt OFF
OFF
I_______I
   
3
Occupancy Mode Away Prompt ON
Occupancy Mode Away Prompt OFF
OFF
I_______I
   
4
Occupancy Mode Night Prompt ON
Occupancy Mode Night Prompt OFF
OFF
I_______I
   
5-8
For future use
[97] View Software Version
[98] Initiate Global Label Broadcast
All LCD programming is done per keypad. If more than one LCD keypad are present on the system, and the PC5400 receives labels, labels pro-
grammed at one keypad can be broadcast to all other LCD keypads. Perform the following procedure in order to broadcast labels:
Step 1 - Program one LCD keypad completely.
Step 2 - Make sure all LCD keypads are connected to the Keybus.
Step 3 - Enter Installer’s Programming, then enter Section [98] at the keypad that was programmed. The keypad will now broadcast all the informa-
tion programmed to all the other LCD keypads on the system.
Step 4 - When the keypad is finished press the [#] key to exit.
[99] Reset LCD EEPROM to Factory Defaults
ASCII Characters 
UL Listed Commercial and Residential Installations
The installation requirements listed below must be met for the follow-
ing grades of service.
Grade A Local
The installation must have a bell UL Listed for mecantile local alarms
(AMSECO MBL10B with model AB-12 bell housing).
The digital communicator must be enabled.
The control panel must be in the Attack Resistant Enclosure (DSC
Model CMC-1).
Swinger shutdown must be disabled.
Grade B Central Station and Police Connect
The installation must have a bell UL Listed for mecantile local alarms
(AMSECO MBL10B with model AB-12 bell housing).
The digital communicator must be enabled.
Ringback must be enabled.
The control panel must be in the Attack Resistant Enclosure (DSC
Model CMC-1).
Swinger shutdown must be disabled.
Grade C Central Station
The digital communicator must be enabled.
Ringback must be enabled.
The control panel must be in the Attack Resistant Enclosure (DSC
Model CMC-1).
Swinger shutdown must be disabled.
All Commercial Installations
The entry delay must not exceed 60 seconds 
The exit delay must not exceed 60 seconds.
The minimum bell cutoff time is 15 minutes.
Residential Installations
The entry delay must not exceed 45 seconds 
The exit delay must not exceed 60 seconds.
The minimum bell cutoff time is 4 minutes.
Programming
The notes in the programming sections describing the system config-
urations for UL Listed installations must be implemented.
Control of the Protected Premises
In order to have a UL Certificated system the protected area is to be
under the responsibility of one ownership and management (i.e. one
business under one name). This may be a group of buildings
attached or unattached with different addresses but under the
responsibility of someone having mutual interest. The person of
mutual interest is not the alarm installing company.
Bell Location
The alarm sounding device (bell) must be located where it can be
heard by the person or persons responsible for maintaining the secu-
rity system during the daily arming cycle.
Protection of the Control Unit
The local control and the local power supply must be protected by
one of the following ways:
The control unit and audible alarm device power supply must be
in a protected area which is armed 24 hours a day.
Each partition shall arm the area protecting the control unit and
the audible alarm device power supply. This may require dupli-
cate protection armed by each partition. Access to this protected
area, without causing an alarm, will require that all partitions be
disarmed.
In all cases described above, the protected area for the control unit
must be programmed as not bypassable.
Casual Users
The installer should caution the user(s) to not give system information
to casual users (e.g. codes, bypass methods, etc. to baby-sitters or
service people). Only the One-Time Use codes should be given to
casual users.
User Information
The installer should advise the users and note in the user instruction
manual:
Service organization name and telephone number
The programmed exit time
The programmed entry time
WWW.DIYALARMFORUM.COM