Siemens A31003-51730-U103-7619 Benutzerhandbuch

Seite von 336
The Elements of a DCO-Script
For internal use only
07/2010
5-84
OScAR-Pro Customized Operator, User Manual
  
  
  
BHB_DCO_05.fm
Controls
5.9.13
Double-click events of Listboxes
Double-clicking on a listbox entry internally leads to sending a message (also see Section 
5.11.8, "The Instruction "BroadcastMessage"") though it is only 
processed on the page the list-
box is located on. The message sent is processed by the function with the same name as the 
listbox in branch “On_Message“.
For the type "PROCESS_CONMBR"
Process status
Here you can:
-1 to filter all subscribers,
1 to filter only subscribers whose processing has not 
started or whose dial-up by the system is momentarily in 
a pause,
to filter only subscribers who are momentarily in the pro-
cess of being called,
to filter only subscribers who could not be reached,
to filter only subscribers who are currently being receiv-
ing the welcome message,
to filter only subscribers for whom the welcome mes-
sage is already over,
to filter only subscribers who have switched themselves 
to mute,
to filter only subscribers who are participating in the 
conference passively (i.e. who do not have the right to 
speak),
10 to filter only subscribers who are participating in the 
conference actively (i.e. who have the right to speak),
11 to filter only subscribers who are currently being 
parked, i.e. who have neither the right to speak nor to lis-
ten to the active conference, and who are being played an 
announcement instead,
256 to filter only subscribers who are participating in the 
conference actively (i.e. 6 and 11),
257 to filter only subscribers who are otherwise participat-
ing in the conference (i.e. 8 and 11),
258 to filter only subscribers who are not yet participating 
in the conference, or
a Constant, Parameter or Variable of the data type int.
Child node
Description
Table 5-63
Attributes of Process filters