The Elements of a DCO-Script
Instructions
5.11.34
The Instruction "SetButtonStaticRect"
Description
Use this Function Instruction to edit the position and size of a Static element on a Button.
Arguments
Arguments
Description
Button
Editable combobox to define the Button whose Static element 
you want to edit in position and size.
Here you can:
enter the name of the Button direct or
select a Button from the list of all available Buttons.
Static element
Editable combobox to enter the Static element of the selected 
Button, the position and size of which you want to edit.
Here you can:
enter the name of the Static element direct or
select a Static element from the list of all Static elements 
that are available.
Editable combobox to define the left and upper (top) margin as 
well as the width and the height in pixels.
Here you can:
enter a numeric value,
assign a Constant, Parameter or Variable of the data type 
int, or
assign a reference to a Control that has the data type int.
Table 5-102