The Elements of a DCO-Script
Instructions
5.11.46
The Instruction "SetCheckBoxStatus"
Description
Use this Function Instruction to edit the way in which a Checkbox is output and used.
Arguments
Arguments
Description
Checkbox
Editable combobox to choose the Checkbox you want to edit 
with regard to the way in which it is output and used.
Here you can:
enter the name of the Checkbox direct or
select a Checkbox from the list of all Checkboxes that are 
available.
Status
Editable combobox to specify the way in which the selected 
Checkbox is output and used.
Here you can:
choose to hide the Checkbox,
choose to show the Checkbox and enable entries,
choose 2 to output the Checkbox but block all entries,
assign a Constant, Parameter or Variable of the data type 
uint, or
assign the reference to a Control that has the data type 
uint.
Table 5-114