Siemens A31003-51730-U103-7619 Benutzerhandbuch
BHB_DCO_05.fm
07/2010
OScAR-Pro Customized Operator, User Manual
OScAR-Pro Customized Operator, User Manual
5-155
For internal use only
The Elements of a DCO-Script
Instructions
5.11.59
The Instruction "SetEditText"
Description
Use this Function Instruction to change the content (text) of the Edit field.
Arguments
Arguments
Description
Edit field
Editable combobox to specify the Edit field whose content you
want to edit.
Here you can:
want to edit.
Here you can:
●
enter the name of an Edit field direct or
●
select an Edit field from the list of all Edit fields that are
available.
available.
Text
Editable combobox to enter the content of the Edit field.
Here you can:
Here you can:
●
enter a string,
●
assign a Constant, Parameter or Variable of the data type
string,
string,
●
assign the reference to a Control that has the data type
string.
string.
Table 5-127
The arguments of the Instruction SetEditText