Siemens A31003-51730-U103-7619 Benutzerhandbuch

Seite von 336
BHB_DCO_05.fm
07/2010
OScAR-Pro Customized Operator, User Manual
5-173
   
  
  
For internal use only
The Elements of a DCO-Script
Instructions
5.11.76
The Instruction "SetStaticPictureName"
Description
Use this Function Instruction to change the image of a Static element.
Arguments
Arguments
Description
Static element
Editable combobox to choose the Static element whose image 
you want to edit.
Here you can:
enter the name of the Static element direct or
select a Static element from the list of all Static elements 
that are available.
Image
Editable combobox to define the image you want to assign to 
the Static element.
Here you can:
enter a file name from the List of images,
select an image in the user window that opens as you 
click the entry "Select image..." in the drop down list (see 
Section 4.6.2, "Administration of the Image lists"),
assign a Constant, Parameter or Variable of the data type 
string,
assign the reference to a Control that has the data type 
string.
Table 5-144
The arguments of the Instruction SetStaticPictureName