Server Alarms
104 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
7
S8300
MAJ
“Application <name> not started, parm file errors” — Since an
application’s specified location in watchd.conf is incorrect, Watchdog
application’s specified location in watchd.conf is incorrect, Watchdog
cannot start the application.
1. To verify the alarm, look for the application’s or process ID (PID),
either using the:
- Web interface, by selecting Diagnostics > View System Logs and
Watchdog Logs
- Linux command line, by entering logv -w or, directly, by
examining /var/log/ecs/wdlog.
2. Verify that the executable file named in the log exists and is
executable.
To locate the application’s executable file, enter the Linux command:
ls -l /opt/ecs/sbin/appl
If the executable is present, Linux returns a symbolic link to its
location.
location.
3. If so (less common):
a. Enter ls -l on the symbolic link’s address.
b. Verify that the executable has “execution” permissions.
b. Verify that the executable has “execution” permissions.
c. If not, enter chmod +x to enable execution of the application.
If not — Linux has returned a “null link” (more common):
- Acquire the executable from the CD.
4. Verify that the string in watchd.conf is correct.
5. Enter start -s application to start the application.
6. Manually clear the alarm, either from the:
5. Enter start -s application to start the application.
6. Manually clear the alarm, either from the:
- Web interface, by selecting Alarms and Notification, the
appropriate alarm, and Clear
- Linux command line, by entering almclear -n #id
Table 31: _WD Alarms in Media Server (continued)
Event
ID
Alarm
Level
Level
Alarm Text, Cause/Description, Recommendation