Avaya 03-300430 Benutzerhandbuch

Seite von 2574
EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005
1233
 
5001
FAIL
Initialization failure: the EI circuit pack reset successfully and restarted 
execution, but the EI circuit pack could not synchronize itself during 
hardware initialization.
1. Enter reset board PCSS. If the circuit pack is in the active link, this 
procedure can be very destructive. If a test board PCSS shows 
every test passing, and there is no standby link to which you can 
switch, perform this reset at a time when service is least disrupted by 
losing use of the PN.
2. If the reset fails with the same error code, execute test tone-clock 
PC where P is the network that contains this EI circuit pack and C is the 
carrier that contains the active Tone-Clock on network P. Also look for 
SYNC and TONE-BD errors. Resolve any SYNC and TONE-BD errors 
by following the Maintenance documentation for these MOs. Then 
execute reset board PCSS.
3. If the EI circuit pack still fails to reset with the same error code, replace 
the EI circuit pack.
5002
FAIL
Initialization failure: EI circuit pack reset successfully and restarted 
execution. But the EI circuit pack has determined that a lightwave 
transceiver was not attached to the backplane connector when the EI 
circuit pack was last reset. If this system does not have duplicate EI links, 
every user in the PN will be without service until this problem is resolved. If 
this system does have duplicate links, the backup EI link is unavailable 
until this problem is resolved.
1. Attach lightwave transceiver to 25-pair backplane connector in slot 
belonging to EI circuit pack.
2. Reset the circuit pack again.
3. If the reset fails with an Error Code other than 5002, refer to the 
appropriate maintenance section.
4. If the reset fails again with Error Code 5002, replace the lightwave 
transceiver, reset the circuit pack, and execute test board PCSS 
again.
5. If the reset fails again with Error Code 5002, the new lightwave 
transceiver may be defective, or the EI circuit pack may need to be 
replaced.
Table 417: Test #224 Expansion Interface Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 5