Avaya 03-300430 Benutzerhandbuch

Seite von 2574
Communication Manager Maintenance-Object Repair Procedures
1770 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1000
ABRT
Could not get translation information for port.
1. Verify that port circuit is administered.
2. Wait one minute and attempt the test again.
3. If the test continues to abort and the port is not in use, escalate the 
problem.
1005
ABRT
This test is not applicable to the given hardware configuration.
1. This abort message can be ignored.
1020
ABRT
Internal Software Error.
1. Retry the command at one-minute intervals a maximum of 5 times.
1030
ABRT
Internal software group identifier for data module not valid.
1. Verify that port circuit is administered correctly.
2. If administration data correct, escalate the problem.
1031
ABRT
Extension number not valid.
1032
ABRT
Extension number not correct length.
1. Verify that the data module extension is administered correctly.
2. If the administration data is correct, escalate the problem.
1071
ABRT
No auxiliary port on Netcon circuit pack available to test with.
1. Check that the Netcon data channels are administered (the list 
data-modules command should show at least one Netcon-type 
data module).
2. Test the Network Control (Netcon) circuit pack using the test 
data-module command for the Netcon circuit pack.
3. If administration data is correct, escalate the problem.
Table 654: Test #175 Data Module Internal Loop-Around Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 4 of 6